Part Number Hot Search : 
GE33C AAP152 MMBD353 CX4005NL A1104E AD8031AR H21L1 00402
Product Description
Full Text Search
 

To Download U2901A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  keysight technologies u2300a series usb modular multifunction data acquisition devices data sheet
the keysight technologies, inc. u2300a series usb modular multifunction data-acquisition (daq) devices offer a high-performance pc data-acquisition solution. the u2300a series daq devices consist of two families: the basic multifunction daq comes in four models while the high density multifunction daq is made up of three models. the u2300a series daq devices applications extend across industrial and education environments. extending across industrial and education environments, the u2300a series daq with fast sampling rates is well suited for research and development, manufacturing as well as design validation designers. features C up to 3 msa/s sampling rate for a single channel C functions as a standalone or modular unit C easy to use: plug-and-play and hot swappable with hi-speed usb 2.0 C up to 384 channels when incorporated into u2781a keysight modular product chassis C easy-to-use bundled software for quick setup and data logging to pc C 12-bit or 16-bit analog-to-digital (a/d) resolution C 24-bit programmable digital input/output C self-calibration capability C compatible with a wide range of application development environments C usb 2.0 and usbtmc-usb488 standards introduction
3 high sampling rate the u2300a series daq devices can generate sampling rates of up to 3 msa/s for a single channel. when multiple channels are configured, the device can sample data up to 1 msa/s. the fast sampling capability allows users to perform intermittent detection easily. this is ideal when dealing with high density analog input/output signals especially when juggling between different input ranges and sampling requirements. flexible standalone or modular capability the u2300a series daq devices are uniquely designed with the flexibility to function as a standalone unit or as a part of a modular unit. when used together with the u2781a modular product chassis, the devices has the capability to sup - port up to 384 channels. flexible system and control options with polling and continuous mode the u2300a series daq devices have two modes, polling mode and continuous mode. selecting continuous mode enables you to acquire data continuously once the trigger signal is received. arbitrary waveform designed to support arbitrary waveforms, the u2300a series allows you to generate arbitrary waveform via the keysight measurement manager application software or scpi commands. burst mode equipped with the burst mode, the enhancement feature enables simultaneous mode for analog input acquisition. now can you can perform sampling measure - ment up to the highest possible speed of the daq. trigger sources u2300a series offers various trigger options from immediate trigger (none), analog/external digital trigger, system synchronous interface (ssi)/ star trigger and master/slave trigger sources. these entire trigger options has the capability to configure trigger sources during a/d and digital-to-analog (d/a) operations. selecting the slave trigger and ssi/star trigger are recommended when the usb modules are used together with the keysight u2781a usb modular product chassis. predefned function generator aside from supplying dc voltage, the two analog output channels are capable of generating common and predefined waveforms such as sinusoidal wave, square wave, triangle wave, sawtooth wave and noise wave.
4 product characteristics and general specifcations remote interface C hi-speed usb 2.0 C usbtmc-usb488 1 power requirement C +12 vdc (typical) C 2 a (max) input rated current power consumption +12 vdc, 550 ma maximum operating environment C operating temperature from 0 c to +55 c C relative humidity at 15% to 85% rh (non-condensing) C altitude up to 2000 meters C pollution degree 2 C for indoor use only storage compliance C20 c to 70 c safety compliance certifed with: C iec 61010-1:2001/en 61010-1:2001 (2nd edition) C usa: ul61010-1: 2004 C canada: csa c22.2 no.61010-1:2004 emc compliance C iec/en 61326-1 1998 C cispr 11: 1990/en55011:1991, class a, group 1 C canada: ices-001: 1998 C australia/new zealand: as/nzs 2064.1 shock and vibration tested to iec/en 60068-2 io connector 68-pin female vhdci type dimension (w d h) module dimension: C 120.00 mm 182.40 mm 44.00 mm (with plastic casing) C 105.00 mm 174.54 mm 25.00 mm (without plastic casing) terminal block dimension: C 103.00 mm 85.20 mm 42.96 mm weight C 565 g (with plastic casing) C 400 g (without plastic casing) warranty three years for u2300a series daq devices three months for standard shipped accessories product outlook and dimensions front view rear view top view standard shipped accessories C ac/dc power adapter C power cord C usb extension cable C l-mount kit (used with modular product chassis) C keysight usb modular products quick start guide C keysight usb modular products reference cd-rom C keysight automation-ready cd-rom (contains the keysight io libraries suite) C certifcate of calibration optional accessories C U2901A terminal block and scsi-ii 68- pin connector with 1-meter cable C u2902a terminal block and scsi-ii 68- pin connector with 2-meter cable 120.00 mm 182.40 mm 44.00 mm 1 compatible with microsoft windows operating systems only. requires a direct usb connection to the pc so the appropriate driver can be installed in the usb daq module.
5 electrical specifcations basic multifunction usb daq model number u2351a u2352a u2353a u2354a analog input resolution 16 bits, no missing codes number of channels 16 se/8 di (software selectable/channel) maximum sampling rate 1 250 ksa/s 500 ksa/s scan list memory up to 100 selectable channel entries programmable bipolar input range 10 v, 5 v, 2.5 v, 1.25 v programmable unipolar input range 0 to 10 v, 0 to 5 v, 0 to 2.5 v, 0 to 1.25 v input coupling dc input impedance 1 g / 100 pf operational common mode voltage range 7.5 v maximum overvoltage protection power-on: continuous 30 v, power-off: continuous 15 v trigger sources external analog/digital trigger, ssi/star trigger 2 trigger modes pre- trigger, delay-trigger, post-trigger, and middle-trigger fifo buffer size up to 8 msa analog output resolution 16 bits - 16 bits - number of channels 2 - 2 - maximum update rate 1 msa/s - 1 msa/s - output ranges 0 to 10 v, 10 v, 0 to ao_ext_ref, ao_ext_ref 3 - 0 to 10 v, 10 v, 0 to ao_ext_ref, ao_ext_ref 3 - output coupling dc - dc - output impedance 0.1 typical - 0.1 typical - stability any passive load up to 1500 pf - any passive load up to 1500 pf - power-on state 0 v steady state - 0 v steady state - trigger sources external analog/digital trigger, ssi/star trigger 2 - external analog/digital trigger, ssi/star trigger 2 - trigger modes post-trigger and delay-trigger - post-trigger and delay-trigger - fifo buffer size one channel: maximum 8 msa two channels: maximum 4 msa/ch - one channel: maximum 8 msa two channels: maximum 4 msa/ch - function generation mode sine, square, triangle, sawtooth, and noise waveforms - sine, square, triangle, sawtooth, and noise waveforms -
6 basic multifunction usb daq (continued) iit number of channels 24-bit programmable input/output compatibility ttl input voltage v il = 0.7 v max, i il = 10 a max v ih = 2.0 v min, i ih = 10 a max input voltage range C0.5 v to +5.5 v output voltage v ol = 0.45 v max, i ol = 8 ma max v oh = 2.4 v min, i oh = 400 a max general purpose digital counter maximum count (231C1) bits number of channels two independent up/down counter compatibility ttl clock source internal or external base clock available 48 mhz maximum clock source frequency 12 mhz input frequency range 4 0.1 hz to 6 mhz at 50% duty cycle pulse width measurement range 0.167 s to 178.956 s analog trigger trigger source all analog input channels, external analog trigger (exta_trig) trigger level full scale for internal; 10 v for external trigger conditions above high, below low, and window (software selectable) trigger level resolution 8 bits bandwidth 400 khz input impedance for exta_trig 20 k coupling dc overvoltage protection continuous for 35 v maximum digital trigger compatibility ttl/cmos response rising or falling edge pulse width 20 ns minimum calibration 5 on board reference voltage 5 v temperature drift 2 ppm/c stability 6 ppm/1000 hrs general remote interface hi-speed usb 2.0 device class usbtmc-usb488 programmable interface standard commands for programmable instruments (scpi) and ivi-com 1 when multiple channels are used, the sampling rate of each channel is the maximum sampling rate divided by the number of channels used. 2 system synchronous interface (ssi) and star trigger commands are used when modular devices are used in the product chassis. 3 maximum external reference voltage for analog output channels (ao_ext_ref) is 10 v. 4 measurement frequencys resolution: = 12 mhz/n, n = 2, 3, 4, 5, ..., 120 m = 6 mhz, 4 mhz, 3 mhz, 2.4 mhz, 2.0 mhz, ..., 0.1 hz (up to six decimal points) 5 20 minutes warm-up time is recommended.
7 high density multifunction usb daq model number u2355a u2356a u2331a analog input resolution 16 bits, no missing codes 12 bits, no missing codes number of channels 64 se/32 di (software selectable/channel) maximum sampling rate 1 250 ksa/s 500 ksa/s 3 msa/s (single channel) 1 msa/s (multiple channels) scan list memory up to 100 selectable channel entries programmable bipolar input range 10 v, 5 v, 2.5 v, 1.25 v 10 v, 5 v, 2.5 v, 1.25 v, 1 v, 0.5 v, 0.25 v, 0.2 v, 0.05 v programmable unipolar input range 0 to 10 v, 0 to 5 v, 0 to 2.5 v, 0 to 1.25 v 0 to 10 v, 0 to 5 v, 0 to 4 v, 0 to 2.5 v, 0 to 2 v, 0 to 1 v, 0 to 0.5 v, 0 to 0.4 v, 0 to 0.1v input coupling dc input impedance 1 g / 100 pf operational common mode voltage range 7.5 v maximum overvoltage protection power-on: continuous 30 v, power-off: continuous 15 v trigger sources external analog/digital trigger, ssi/star trigger 2 trigger modes pre- trigger, delay-trigger, post-trigger, and middle-trigger fifo buffer size up to 8 msa analog output resolution 12 bits number of channels 2 maximum update rate 1 msa/s output ranges 0 to 10 v, 10 v, 0 to ao_ext_ref, ao_ext_ref 3 output coupling dc output impedance 0.1 typical stability any passive load up to 1500 pf power-on state 0 v steady state trigger sources external analog/digital trigger, ssi/star trigger 2 trigger modes post-trigger and delay-trigger fifo buffer size one channel: maximum 8 msa two channels: maximum 4 msa/ch function generation mode sine, square, triangle, sawtooth, and noise waveforms digital i/o number of bits 24-bit programmable input/output compatibility ttl input voltage v il = 0.7 v max, i il = 10 a max v ih = 2.0 v min, i ih = 10 a max input voltage range C0.5 v to +5.5 v output voltage v ol = 0.45 v max, i ol = 8 ma max v oh = 2.4 v min, i oh = 400 a max
8 high density multifunction usb daq (continued) ) general purpose digital counter maximum count (231 C 1) bits number of channels two independent up/down counter compatibility ttl clock source internal or external base clock available 48 mhz maximum clock source frequency 12 mhz input frequency range 4 0.1 hz to 6 mhz at 50% duty cycle pulse width measurement range 0.167 s to 178.956 s analog trigger trigger source all analog input channels, external analog trigger (exta_trig) trigger level full scale for internal; 10 v for external trigger conditions above high, below low, and window (software selectable) trigger level resolution 8 bits bandwidth 400 khz input impedance for exta_trig 20 k coupling dc overvoltage protection continuous for 35 v maximum digital trigger compatibility ttl/cmos response rising or falling edge pulse width 20 ns minimum calibration 5 on board reference 5 v temperature drift 2 ppm/c stability 6 ppm/1000 hrs general remote interface hi-speed usb 2.0 device class usbtmc-usb488 programmable interface standard commands for programmable instruments (scpi) and ivi-com 1 when multiple channels are used in the u2355a or u2356a, the sampling rate of each channel is the maximum sampling rate divided by the number of channels used. for multiple channels used in the u2331a, the sampling rate of each channel = (1 msa/s) / number of channels used. 2 system synchronous interface (ssi) and star trigger commands are used when modular devices are used in the product chassis. 3 maximum external reference voltage for analog output channels (ao_ext_ref) is 10 v. 4 measurement frequencys resolution: = 12 mhz/n, n = 2, 3, 4, 5, ..., 120 m = 6 mhz, 4 mhz, 3 mhz, 2.4 mhz, 2.0 mhz, ..., 0.1 hz (up to six decimal points) 5 20 minutes warm-up time is recommended.
9 electrical measurement specifcations basic multifunction usb daq model number u2351a, u2352a u2353a, u2354a analog input measurement 1 function 23 c 5 c 0 c to 18 c 28 c to 45 c 23 c 5 c 0 c to 18 c 28 c to 45 c offset error 1 mv 5 mv 1 mv 5 mv gain error 2 mv 5 mv 2 mv 5 mv C3 db small signal bandwidth 2 760 khz 1.5 mhz 1% thd large signal bandwidth 2 300 khz 300 khz system noise 1 mvrms 2 mvrms 1 mvrms 2.5 mvrms cmrr 62 db 62 db spurious-free dynamic range (sfdr) 3 88 db 82 db signal-to-noise and distortion ratio (sinad) 3 80 db 78 db total harmonic distortion (thd) 3 C90 db C82 db signal-to-noise ratio (snr) 3 80 db 78 db effective number of bits (enob) 3 13 12.6 model number u2351a, u2353a analog output measurement 1 function 23 c 5 c 0 c to 18 c 28 c to 45 c offset error 1 mv 4 mv gain error 4mv 5 mv slew rate 19 v/s rise time 0.9 s fall time 0.9 s settling time to 1% output error 4 s driving capability 5 ma glitch energy 5 ns-v (typical), 80 ns-v (maximum) 1 specifcations are for 20 minutes of warm-up time, calibration temperature at 23 c and input range of 10 v. 2 specifcations are based on the following test condition: bandwidth test model number test conditions (dut setting at 10 v bipolar) C3 db small signal bandwidth 1% thd large signal bandwidth u2351a u2352a sampling rate: input voltage: C C 3 db small signal bandwidth C 1% thd large signal bandwidth 250 ksa/s C 10% fsr C fsr C1 db fs u2353a u2354a sampling rate: input voltage: C C3 db small signal bandwidth C 1% thd large signal bandwidth 500 ksa/s C 10% fsr C fsr C1 db fs 3 specifcations are based on the following test conditions: dynamic range test model number test conditions (dut setting at 10 v bipolar) sfdr, thd, sinad, snr, enob u2351a u2352a C sampling rate: C fundamental frequency: C number of points: C fundamental input voltage: 250 ksa/s 2.4109 khz 8192 fsr C1 db fs u2353a u2354a C sampling rate: C fundamental frequency: C number of points: C fundamental input voltage: 500 ksa/s 4.974 khz 16384 fsr C1 db fs
10 high density multifunction usb daq model number u2355a u2356a u2331a analog input measurement 1 function 23 c 5 c 0 c to 18 c 28 c to 45 c 23 c 5 c 0 c to 18 c 28 c to 45 c 23 c 5 c 0 c to 18 c 28 c to 45 c offset error 1 mv 2 mv 1 mv 2 mv 2 mv 3 mv gain error 2 mv 3 mv 2 mv 6 mv 6 mv 7.5 mv C3 db small signal bandwidth 2 760 khz 1.3 mhz 1.2 mhz 1% thd large signal bandwidth 2 400 khz 400 khz n/a system noise 1 mvrms 2 mvrms 1 mvrms 4 mvrms 3 mvrms 5 mvrms cmrr 64 db 61 db 62 db spurious-free dynamic range (sfdr) 3 88 db 86 db 71 db signal-to-noise and distortion ratio (sinad) 3 80 db 78 db 72 db total harmonic distortion (thd) 3 C90 db C84 db C76 db signal-to-noise ratio (snr) 3 80 db 78 db 72 db effective number of bits (enob) 3 13 12.6 11.6 bandwidth test model number test conditions (dut setting at 10 v bipolar) C3 db small signal bandwidth 1% thd large signal bandwidth u2355a sampling rate: input voltage: C C3 db small signal bandwidth C 1% thd large signal bandwidth 250 ksa/s 10% fsr fsr C1 db fs u2356a sampling rate: input voltage: C C3 db small signal bandwidth C 1% thd large signal bandwidth 500 ksa/s 10% fsr fsr C1 db fs u2331a sampling rate: input voltage: C C3 db small signal bandwidth C 1% thd large signal bandwidth 3 msa/s 10% fsr fsr C1 db fs 3 specifcations are based on the following test conditions. dynamic range test model number test conditions (dut setting at 10 v bipolar) C3 db small signal bandwidth 1% thd large signal bandwidth u2355a C sampling rate: C fundamental frequency: C number of points: C fundamental input voltage: 250 ksa/s 2.4109 khz 8192 fsr C1 db fs u2356a C sampling rate: C fundamental frequency: C number of points: C fundamental input voltage: 500 ksa/s 4.974 khz 16384 fsr C1 db fs u2331a C sampling rate: C fundamental frequency: C number of points: C fundamental input voltage: 3 msa/s 29.892 khz 65536 fsr C1 db fs 1 specifcations are for 20 minutes of warm-up time, calibration temperature at 23 c and input range of 10 v. 2 specifcations are based on the following test conditions.
11 high density multifunction usb daq (continued) model number u2355a, u2356a u2331a analog output measurement 1 unction 23 c 5 c 0 c to 18 c 28 c to 45 c 23 c 5 c 0 c to 18 c 28 c to 45 c offset error 1 mv 4 mv 1.5 mv 3 mv gain error 4 mv 5 mv 4 mv 5 mv slew rate 19 v/s 19 v/s rise time 0.9 s 0.9 s fall time 0.9 s 0.9 s settling time to 1% output error 4 s 4 s driving capability 5 ma 5 ma glitch energy 5 ns-v (typical), 80 ns-v (maximum) 5 ns-v (typical), 80 ns-v (maximum) 1 specifcations are for 20 minutes of warm-up time, calibration temperature at 23 c and input range of 10 v.
12 dc characteristics accuracy specifcations model number u2351a, u2352a, u2353a, u2354a analog input unipolar range (v) offset error (mv) 1 gain error (mv) accuracy (% of reading + offset error) 2 10 1.5 2.0 0.04% + 1.5 mv 5 1.5 2.0 0.08% + 1.5 mv 2.5 1.0 1.0 0.08% + 1.0 mv 1.25 1.0 1.0 0.16% + 1.0 mv bipolar range (v) offset error (mv) 1 gain error (mv) accuracy (% of reading + offset error) 2 10 1.0 2.0 0.02% + 1.0 mv 5 1.0 2.0 0.04% + 1.0 mv 2.5 1.0 1.5 0.06% + 1.0 mv 1.25 1.0 1.5 0.12% + 1.0 mv model number u2355a, u2356a unipolar range (v) offset error (mv) 1 gain error (mv) accuracy (% of reading + offset error) 2 10 1.0 1.5 0.03% + 1.0 mv 5 1.0 1.5 0.06% + 1.0 mv 2.5 1.0 1.0 0.08% + 1.0 mv 1.25 1.0 1.0 0.16% + 1.0 mv bipolar range (v) offset error (mv) 1 gain error (mv) accuracy (% of reading + offset error) 2 10 1.0 2.0 0.02% + 1.0 mv 5 1.0 2.0 0.04% + 1.0 mv 2.5 1.0 1.5 0.06% + 1.0 mv 1.25 1.0 1.5 0.12% + 1.0 mv model u2331a unipolar range (v) offset error (mv) 1 gain error (mv) accuracy (% of reading + offset error) 2 10 1.5 4.0 0.08% + 1.5 mv 5 1.5 2.0 0.08% + 1.5 mv 4 1.5 2.0 0.10% + 1.5 mv 2.5 1.0 1.5 0.12% + 1.0 mv 2 1.0 1.0 0.10% + 1.0 mv 1 1.0 1.0 0.20% + 1.0 mv 0.5 1.0 1.0 0.41% + 1.0 mv 0.4 1.0 1.0 0.51% + 1.0 mv 0.1 1.0 1.0 2.04% + 1.0 mv C the above specifcations are typical for 23 c. C specifcations are for 20 minutes warm-up and self calibration. C the measurement are calculated with 100 points avearaging of data. 1 offset error is measured at midscale of full range. 2 accuracy = [% of |(gain error / (measured value C midscale of fsr))| + offset error]
13 accuracy specifcations (continued) model u2331a ipolar range (v) offset rror (mv) 1 gain rror (mv) accuracy ( of reading offset error) 2 10 2.0 6.0 0.06% + 2.0 mv 5 1.5 4.0 0.08% + 1.5 mv 2.5 1.5 2.0 0.08% + 1.5 mv 1.25 1.0 1.5 0.12% + 1.0 mv 1 1.0 1.0 0.10% + 1.0 mv 0.5 1.0 1.0 0.20% + 1.0 mv 0.25 1.0 1.0 0.40% + 1.0 mv 0.2 1.0 1.0 0.50% + 1.0 mv 0.05 1.0 1.0 2.02% + 1.0 mv C the above specifcations are typical for 23 c. C specifcations are for 20 minutes warm-up and self calibration. C the measurement are calculated with 100 points averaging of data. model u2351a, u2352a, u2353a, u2354a analog output unipolar range (v) offset rror (mv) 3 gain rror (mv) accuracy ( of reading offset error) 4 10 1.0 2.0 0.02% + 1.0 mv bipolar range (v) offset error (mv) 3 gain error (mv) accuracy (% of reading + offset error) 4 10 1.0 4.0 0.04% + 1.0 mv model u2355a, u2356a unipolar range (v) offset rror (mv) 3 gain rror (mv) accuracy ( of reading offset error) 4 10 1.0 2.0 0.02% + 1.0 mv bipolar range (v) offset error (mv) 3 gain error (mv) accuracy (% of reading + offset error) 4 10 1.0 4.0 0.04% + 1.0 mv model u2331a unipolar range (v) offset rror (mv) 3 gain rror (mv) accuracy ( of reading offset error) 4 10 2.5 4.0 0.04% + 2.5 mv bipolar range (v) offset error (mv) 3 gain error (mv) accuracy (% of reading + offset error) 4 10 1.5 4.0 0.04% + 1.5 mv C the above specifcations are typical for 23 c. C specifcations are for 20 minutes warm-up and self calibration. 1 offset error is measured at midscale of full range. 2 accuracy = [% of |(gain error / (measured value C midscale of fsr))| + offset error] 3 offset error is measured at 0 v. 4 accuracy = [% of |gain error/output value| + offset voltage]
14 the keysight measurement manager (amm) is an application data viewer software that comes with the standard purchase of the u2300a series usb modular data acquisition. this software is designed to help you perform quick device configuration, data logging and data acquisition using the products. supported features found in the u2300a series usb modular multi - function data acquisition devices: C averaging C command logger C self-calibration C option to save the current instrument configuration to a file C data logging and export feature to csv, html and text only format files that can be printed C data viewer to load and review previously logged data C trigger settings between modules in the instrument chassis with star trigger and master/slave trigger C synchronization display and data logging for modules in the instrument chassis keysight measurement manager keysight measurement manager prerequisites prior to installing the keysight measurement manager software, ensure that your pc meets the following minimum system requirements for installation and operations. requirement windows xp operating systems windows vista operating systems windows 7 operating systems operating system windows xp service pack 3 (or later) 1 windows vista (32-bit) service pack 1 and 2 2 windows 7 (32-bit and 64-bit) 3, 4 processor speed 600 mhz or higher required, 800 mhz recommended 1 ghz 32-bit (x86) 3 ghz 32-bit (x86) memory 256 mb minimum (1 gb or greater recommended) 1 gb minimum 2 gb minimum hard-disk space 1.5 gb minimum 1.5 gb minimum 1.5 gb minimum video super vga (800 600) 256 colors or more support for directx 9 graphics with 128 mb graphics memory recommended 5 support for directx 9 graphics with 128 mb graphics memory recommended 5 cd-rom drive or dvd-rom drive 6 required required required browser microsoft internet ex - plorer 5.01 or greater microsoft internet explorer 7 or greater microsoft internet explorer 7 or greater 1 supported windows xp editions home or professional 2 supported windows vista (32-bit) editions home basic, home premium, business, or ultimate 3 supported windows 7 (32-bit and 64-bit) editions home basic, home premium, professional, enterprise, or ultimate 4 keysight measurement manger for windows 7 64-bit support is a 32-bit application running on a wow64 (windows-on-windows 64-bit) emulator. 5 super vga graphics is supported for windows vista and windows 7. 6 the type of media provided with the product determines whether a cd-rom drive or dvd-rom drive is required. software requirements keysight io libraries suite 15.1 and above 1 keysight t&m toolkit runtime version 2.1 2 keysight t&m toolkit redistributable package 2.1 patch 2 microsoft .net framework version 2.0 2 1 available on the keysight automation-ready cd-rom. 2 bundled with keysight measurement manager software application installer.
15 other products in the keysight usb modular data acquisition (daq) family u2500a series usb modular simultaneous sampling multifunction daq features: C high analog input sampling rate coverage of up to 2 msa/s for a each channel C high speed usb 2.0 C simultaneous acquisition of multiple data points C multifunction capabilities analog input (ai), analog output (ao), digital input output (dio), and counter for more information: www.keysight.com/find/u2500a u2600a series usb modular isolated digital i/o features: C 64 opto-isolated lines that can meet demand up to 24 v C high speed usb 2.0 C isolation voltage of 1250 vrms for protection from transient voltage spikes for more information: www.keysight.com/find/u2600a u2781a usb modular product chassis features: C expansion of channels for each modular product C multiple instrument synchronization C internal and external 10 mhz reference clock C high-speed usb 2.0 C ssi/star trigger bus synchronization between external trigger source and modules for more information: www.keysight.com/find/u2781a
16 optional accessories features to meet your demands C 31 input channels that can be independently configured to either differential thermo - couple input mode, single-ended voltage input mode, or differential voltage input mode using two input channels set to voltage input mode C supports the standard thermocouple types (j, k, r, s, t, n, e, and b) defined in the nist its-90 thermocouple database C error detection for open thermocouple channels C built-in isothermal construction on terminal block for improved measurement accuracy C built-in thermistor for cold junction compensation C built-in zeroing function to compensate for overall system offset errors due to tem - perature drift and long term drift C up to 10 v input voltage range for higher voltage inputs C sampling rate of 500 ksa/s for overall module C sampling rate of 10 ksa/s total for all channels in thermocouple mode C quick and easy usb setup C robust, cost-effective, and user friendly applications the u2802a thermocouple input device is designed for robust and demanding industrial applications. this product is suitable and ideal for thermocouple measurement applications such as; C product thermal analysis and characterization C environmental chamber profiling C process monitoring in consumer electronics markets C material properties testing in education environments C study of electronic temperature properties C appliances testing the keysight u2802a is a 31-channel thermocouple signal conditioning module with a built-in thermistor for cold junction compensation. the u2802a is designed to convert low input voltage signals (less than 100 mv) from a thermocouple into an output voltage range suitable for data acquisition devices (10 v). the u2802a device is to be used in conjunction with the keysight u2355a or u2356a model daq device to enable temperature measurements using thermocouples. it works as a standalone device attached to a single daq device via two scsi-ii 68 conductor cables. designed with the compatibility to complement eight standard thermocouple types, it caters to a wide range of applications in various industrial settings. 16
17 thermocouple input mode in thermocouple input mode, the u2802a can acquire up to 100 mv input signals. each channel includes an instrumentation amplifier and a 4 hz low-pass filter. the low-pass filter removes unwanted noise from the thermocouple wires to obtain accurate measurement data. voltage input mode alternatively, you can select separate voltage input modes for each channel. the channel will be set to bypass the amplifier and filter, allowing up to 10v input signals to be directly routed to the daq device analog input. the bandwidth in this mode is more than 500 khz. zero mode in zero mode, the positive and nega - tive inputs of the instrumentation amplifier are shorted together. the voltage measured in this mode corresponds to the offset voltage of the channel. you can subtract this offset voltage from subsequent thermocouple mode measurements to increase measurement accuracy. this mode is only applicable in thermo - couple mode. thermocouple compatibility the u2802a is compatible with a wide range of standard thermo - couple types defined in the nist its-90 thermocouple database. this includes types j, k, r, s, t, n, e, and b. open thermocouple detection the u2802a includes open ther - mocouple detection circuitry to indicate the presence of an open thermocouple. calibration eeprom the u2802a gain and offset calibra - tion factors for each channel are stored in the eeprom during fac - tory calibration and can be retrieved prior to taking measurements. this on-board eeprom also stores the module id, serial number, and date of calibration for your reference. a sec - tion of the eeprom is also allocated for you to save your calibration data. restoring factory calibration using the amm software, you can easily restore the u2802a calibration data from your settings to the original factory settings. 17
18 product characteristics and general specifcations power consumption +12 vdc, 480 ma maximum operating environment C operating temperature from 0 c to +55 c C relative humidity at 50% to 85% rh (non-condensing) C altitude up to 2000 meters storage compliance C40 c to 70 c safety compliance certifed with: C iec 61010-1:2001/en 61010-1:2001 (2nd edition) emc compliance C iec 61326-1:2002/en 61326-1:1997+a2:2001+a3:2003 C cispr 11: 1990/en 55011:1990-group 1 class a C canada: ices-001:2004 C australia/new zealand: as/nzs cispr 11:2004 shock and vibration tested to iec/en 60068-2 io connector C 2 68-pin female scsi connector C 2 34 pin screw terminal block C 1 24 pin screw terminal block dimension (w d h) 158.70 mm 254.20 mm 40.50 mm weight 1.036 kg warranty three years for u2802a three months for standard shipped accessories product outlook and dimensions front view rear view top and side view standard shipped accessories C power supply splitter C two 68-pin scsi cables (1 m) C one j-type thermocouple C keysight u2802a 31-channel thermocouple input device quick start guide C keysight usb modular products reference cd-rom C keysight automation-ready cd-rom (contains the keysight io libraries suite) C certifcate of calibration 40.05 mm 158.70 mm 254.20 mm
19 product specifcations general characteristics number of channels 31 differential and 1 cjc input voltage range for voltage mode 10 v (signal + common mode) input voltage (thermocouple mode) 100 mv sampling rate for thermocouple mode 10 ksa/s total for all channels sampling rate for overall module 500 ksa/s thermocouple types j, k, r, s, t, n, e, and b input specifcations accuracy (thermocouple mode) C overall gain error C overall offset error C nonlinearity 0.06% (23 c 5 c ) 15 v (without zeroing) (23 c 5 c ) 6 v (with zeroing) < 0.005% of full scale range system noise (rms) C gain ( 1) C gain ( 100) 100 vrms 5 vrms common mode rejection ratio (cmrr) C voltage mode C thermocouple mode > 60 db > 80 db cold junction accuracy 1.0 c typical (23 c 5 c ) 1.5 c typical (0 c to 18 c, 28 c to 55 c) input characteristics bandwidth (voltage mode) > 500 khz bandwidth (thermocouple mode) 4.0 hz overvoltage protection 1 tc mode 2 C common mode: 17 v (tc+ and tcC with respect to gnd) C differential mode: 7 v (differential voltage between tc+ and tcC) bypass mode 20 v (tc+ input with respect to gnd) power-off mode 11 v (tc+, tcC input with respect to gnd) input impedance > 1 g input bias current 2.5 na max input offset current 1.5 na max gain drift 60 ppm/c max offset drift 1 v/c max filter cutoff frequency (C3 db) (thermocouple mode) 4.0 hz filter type (thermocouple mode) low pass rc filter other features recommended warm up time 30 minutes 1 the overvoltage protection levels specifed above indicate the maximum voltage each input pin can tolerate without resulting in any damages. however, prolonged exposure to these levels may affect device safety and reliability. hence, it should be avoided where possible. 2 on the channels confgured for thermocouple mode, the tc+ and tcC pins can tolerate up to 17 v of differential voltage for a fe w minutes. however, exceeding a voltage range of 100 mv on these channels can cause additional current to be drawn from the devices power supply regulators, which ma y damage the device if multiple channels are overdriven for prolonged periods. this is the case when a voltage source is tied across the tc n + and tc n C pin. voltage sources greater than 100 mv should be tied to tc n + and gnd (foating source), or tc n + and tc n+1 + (grounded source), and have the channels set for bypass mode.
20 thermocouples typical measurement accuracy the u2802a measurement error with u2355a or u2356a at 23 c 5 c is shown below.
21 system accuracy specifcations the u2802a system accuracy specifications are shown in table 1, table 2, and table 3. these measurements are derived from the u2802a and daq input accuracy specifications without including the thermocouple error. refer to calculating system accuracy section in the keysight u2802a 31-channel thermocouple input device users guide for calculation methodology. table 1. measurement accuracy of the u2355a and u2356a at 23 c 5 c thermocouple measurement accuracy (u2355a, u2356a at 23 c 5 c) t/c type its-90 temperature range (c) optimum measurement range(c) without averaging ( c) 50 points averaging ( c) 500 points averaging ( c) low high low high b 0 1820 1100 1820 1.9 1.2 1.0 400 1100 4.4 2.5 2.0 e C270 1000 C150 1000 1.7 1.6 1.6 C200 C150 2.4 2.3 2.3 j C210 1200 C150 1200 1.6 1.5 1.5 C210 C150 2.7 2.6 2.5 k C270 1372 C100 1200 1.5 1.4 1.4 C200 C100 2.7 2.6 2.6 n C270 1300 C100 1300 1.5 1.3 1.3 C200 C100 3.0 2.7 2.6 r C50 1768 300 1760 2.0 1.4 1.3 C50 300 5.0 3.1 2.6 s C50 1768 400 1760 2.1 1.6 1.4 C50 400 4.5 2.8 2.4 t C270 400 C100 400 1.5 1.4 1.4 C200 C100 2.7 2.5 2.5 table 2. measurement accuracy of the u2355a at 0 to 18 c and 28 to 45 c thermocouple measurement accuracy (u2355a at 0 to 18 c and 28 to 45 c) t/c type its-90 temperature range (c) optimum measurement range (c) without |averaging ( c) 50 points averaging ( c) 500 points averaging ( c) low high low high b 0 1820 1100 1820 3.4 2.4 2.2 400 1100 7.5 3.6 2.2 e C270 1000 C150 1000 2.7 2.6 2.5 C200 C150 3.8 3.6 3.6 j C210 1200 C150 1200 2.5 2.4 2.4 C210 C150 4.2 4.0 3.9 k C270 1372 C100 1200 2.9 2.8 2.8 C200 C100 4.3 4.0 3.9 n C270 1300 C100 1300 2.6 2.5 2.5 C200 C100 4.9 4.2 4.0 r C50 1768 300 1760 3.8 3.1 3.0 C50 300 8.5 4.6 3.3 s C50 1768 400 1760 4.2 3.4 3.2 C50 400 7.7 4.2 3.1 t C270 400 C100 400 2.4 2.2 2.2 C200 C100 4.3 4.3 3.9
22 table 3. measurement accuracy of the u2356a at 0 to 18 c and 28 to 45 c thermocouple measurement accuracy (u2356a @ 0 to 18 c and 28 to 45 c) t/c type its-90 temperature range (c) optimum measurement range (c) without averaging ( c) 50 points averaging ( c) 500 points averaging ( c) low high low high b 0 1820 1100 1820 6.1 3.1 2.4 400 1100 14.4 6.3 2.7 e C270 1000 C150 1000 3.0 2.6 2.6 C200 C150 4.2 3.7 3.6 j C210 1200 C150 1200 2.9 2.5 2.5 C210 C150 4.9 4.1 4.0 k C270 1372 C100 1200 3.3 2.9 2.9 C200 C100 5.3 4.2 4.0 n C270 1300 C100 1300 3.4 2.7 2.6 C200 C100 6.8 4.6 4.1 r C50 1768 300 1760 6.2 3.7 3.2 C50 300 15.7 7.2 3.8 s C50 1768 400 1760 6.4 4.0 3.4 C50 400 14.2 6.6 3.4 t C270 400 C100 400 3.0 2.4 2.2 C200 C100 5.3 4.2 3.9
23 u2901/u2902a -terminal block and scsi- ii 68-pin connector with 1-meter/2-meter cable the U2901A/u2902a is a terminal block and scsi-ii 68-pin connector with 1 meter cable or 2 meter cable that can be used conjunction with the u2300a series and u2500a series. terminal block overview front view 103.00 mm 85.20 mm 28.40 mm 42.96 mm side view
24 ordering information model description u2351a 16-channel 250ksa/s usb modular multifunction daq u2352a 16-channel 250ksa/s usb modular multifunction daq; without analog output u2353a 16-channel 500ksa/s usb modular multifunction daq u2354a 16-channel 500ksa/s usb modular multifunction daq; without analog output u2355a 64-channel 250ksa/s usb modular multifunction daq u2356a 64-channel 500ksa/s usb modular multifunction daq u2331a 64-channel 1msa/s usb modular multifunction daq optional accessories model description u2802a u2802a 31-channel thermocouple input device U2901A terminal block and scsi-ii 68-pin connector with 1-meter cable u2902a terminal block and scsi-ii 68-pin connector with 2-meter cable
for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 0800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-09-04-14) mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. keysight is a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. keysight is a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system. three-year warranty www.keysight.com/find/threeyearwarranty keysights commitment to superior product quality and lower total cost of ownership. the only test and measurement company with three-year warranty standard on all instruments, worldwide. keysight assurance plans www.keysight.com/find/assuranceplans up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2008 quality management system keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/ u2300a this information is subject to change without notice. ? keysight technologies, 2012 - 2014 published in usa, august 2, 2014 5991-0566en www.keysight.com 25 | keysight | u2300a series usb modular multifunction data acquisition devices - data sheet